Industrial sectional door repair in Pantin

Shasama Fermetures repairs industrial sectional doors in the logistics halls of Pantin (93), the Cartier-Bresson zone and Pantin Logistique included: door that no longer opens as the lorry approaches or no longer closes behind it, a technician arrives within 20 minutes.

White industrial sectional door, technician on a lift at the upper-left mechanism, springs visible.
  • Arrival within 20 minutesParis and all of Île-de-France
  • Telephone line open 24/7Calls answered day and night, including weekends
  • Quotation before work startsYour approval before any repair
  • Detection tested before the mechanismGround loop, radar and photocells checked before the mechanism

Shasama Fermetures provides industrial sectional door repair in Pantin, in Seine-Saint-Denis, 24 hours a day, 7 days a week, for logistics halls, depots and workshops. This door is also called an industrial garage door. Ground loop cut, radar out of adjustment, photocell dirty or dazzled, board no longer reading its detector: when the door no longer sees the lorry, the technician tests the detection device before touching the mechanism, makes the diagnosis and presents a written quote before the repair.

Simply call us on 01 87 66 40 33 to describe the fault. As soon as you call, a qualified technician heads to your site in Pantin, carrying common spare parts: our teams have 24 years of experience.

Industrial sectional door repair in Pantin: when the hall door no longer sees the lorry

In 2017, the Town of Pantin presented two logistics business zones, the Cartier-Bresson zone and Pantin Logistique; it has since said it keeps the economic vocation of Cartier-Bresson. In a distribution hall, the sectional door can open as a vehicle passes rather than with the button: a magnetic loop under the asphalt, a radar above the opening or a photocell detects the lorry. When it no longer sees anything, or always sees something, the door can look broken with its mechanism intact. Shasama Fermetures checks the detection first, then restores opening on passage: door freed if the door panel has stopped, photocell or board replaced, loop and radar diagnosed, passage tests.

  • What you can see

    The door no longer opens as the lorry approaches

    What it may indicate

    Ground loop cut or loop detector faulty, radar out of adjustment or blocked.

    What to avoid

    Pressing the button again and again to force the detection.

  • What you can see

    The door stays open all the time

    What it may indicate

    Loop or radar detecting continuously: the control box thinks a vehicle is still there.

    What to avoid

    Unplugging the detector to close it: the door can come down on whatever is passing.

  • What you can see

    The door comes down then goes back up before the floor

    What it may indicate

    Photocell dirty, knocked out of line or dazzled by the low sun in line with the opening.

    What to avoid

    Covering or bridging the photocell to close it anyway.

  • What you can see

    The door opens with the button, never on passage

    What it may indicate

    Detector input of the control box or electronic board no longer reading the signal.

    What to avoid

    Opening the live control box to look for the fault.

Fault by fault, what is covered by the automatic industrial sectional door emergency repair, from the detection to the mechanism.

Ground loop, radar, photocells, board: what we check

What is replaced on site and what is announced from the diagnosis: the detection first, the mechanism only if it is at fault.

  • Ground loop : Loop detector checked; if the buried loop itself is cut, reworking the slot in the asphalt is roadworks, flagged in the quote.
  • Opening radar : Detection field, power supply and cable checked; what needs adjusting or replacing is written in the quote.
  • Photocells : Lenses wiped for the test, alignment reset, photocell replaced if it no longer detects; closing tests with the opening clear.
  • Board and detector input : Detector input of the control box tested, board repaired or replaced depending on the diagnosis; we supply AFCA, GFA, NICE and Somfy boards.
  • Passage tests : Opening triggered by a real vehicle, closing behind it, safety devices tried in front of you before the door goes back into service.

For a quote before the visit: photos of the door, the detector or radar and the motor’s identification plate, using the quote form. The written quote reaches you before the work.

Hall in operation: organising vehicle traffic during the call-out

Vehicle traffic is organised with the operator during the call-out, in this order.

  1. 01

    Door stopped, opening clear

    No more presses on the button or the remote control, nobody under the door panel, no vehicle in the opening; watch from the side without touching, and call us saying when the next delivery rounds leave.

  2. 02

    Door held open safely or locked closed

    If the diagnosis shows that only the detection is at fault, the technician decides with you whether the door is held open, controls switched off, for vehicles to pass, or locked closed while the part is awaited.

  3. 03

    Repair, tests, back into service

    The part is fitted in a slot agreed with the operator; the door goes back into service after the repair and tests with a vehicle passing, never before.

Detection restored on a worn door calls for a scheduled industrial sectional door repair, in a slot agreed with the operator.

Telephone line open 24/7

Hall door that no longer sees the lorry in Pantin?

Arrival within 20 minutes, 24/7. Call-out included in the repair price.

Shasama Fermetures technician loading equipment onto the roof of a service vehicle at night.

Motorising a sectional residential garage door: ceiling motor and manual release

Example intervention

The problem : a sectional residential garage door was to be motorised. Before adding a motor, the door has to be well balanced: a ceiling motor drives the top of the door leaf through a carriage running along its rail, and is not designed to lift a door its springs no longer carry.

What we did : we fitted the motor to the ceiling, on its rail, above the raised door leaf. The red cord hanging from the rail works the manual release: pulled, it frees the carriage so the door can be moved by hand, during a power cut for instance.

Inside view of a closed beige residential garage door, with a drill, a tool bag and a stepladder at its foot
Residential garage door closed, tools laid out on the floor for the motorisation
Raised residential garage door opening onto the outside, the motor box open and a tool bag on the tiled floor
Residential garage door open, new motor in its opened box at the foot of the opening
Motor fixed to the ceiling on its rail, with the leaf of the residential garage door raised just below
Residential garage door motor fitted to the ceiling, with the red manual release cord

See our sectional door projects

Industrial sectional door repair prices

The cost depends on the fault, the parts needed, the door type and access to the motor and cabinet. The quote sets out the work and the final amount for approval before repairs begin.

What is included: travel included, written quotation before work starts, diagnosis free when the work is accepted, no night or weekend surcharge, parts and labour guaranteed for 2 years.

Indicative industrial sectional door repair prices, excluding VAT (HT)
ServicePrice
Emergency repair and diagnosis
Emergency repair and unblocking, travel includedFrom 98 € HT
Geared motor and control cabinet diagnosisFrom 148 € HT
Repairs and parts
Replacement lifting cables (pair)From 118 € HT
Replacement torsion springs (pair)From 371 € HT
Panel replacementFrom 246 € HT
Returning the door to its tracks and realignmentFrom 122 € HT
Motor or automation repairFrom 168 € HT
Safety photocells or safety edge (alongside an intervention)From 89 € HT
Loading bay equipment
Dock leveller repairFrom 198 € HT

Quote terms

After diagnosis, the quote details the work, parts, access requirements and agreed appointment. No additional work starts without your agreement.

Prices excl. VAT (HT), 20 % VAT on top. Final amount set by quotation, presented before any work.

  • fault and component involved
  • manual or motorised door, dimensions and panel type
  • parts and adjustments selected after diagnosis
  • access to the loading bay, motor and control cabinet

Online quote

Industrial sectional door out of service in Pantin? Request a quote

Attach photos of the door and of its rating plate. The written quote is presented before the work.

Request a quote

Photos accepted

Logistics hall doors in Pantin: your questions

Bent connecting arm between the motor and the sectional door: what should I do?

Stop the controls. The arm links the trolley of the ceiling motor to the top panel of the door; bent, it often means the door jammed while the motor was pushing or pulling. Do not straighten it: once bent, it can give way at the next operation. The technician replaces the arm, then looks for what jammed the door, a roller out, a track out of line or lost balance, otherwise the new arm can bend in turn.

Broken stop at the end of the track: can the sectional door come off the track?

Yes. At the end of the horizontal tracks, the stop holds the top rollers when the door is open; broken, the rollers are no longer stopped at the end of travel and a roller can come out of the track. Leave the door where it is, keep people away and call us. The technician replaces the stop, puts the roller back in its guide if it has come out and checks that the door’s top stop is correctly set.

Sectional door opening radar no longer triggering: what should I check?

From inside, without climbing: does the radar’s light come on as a vehicle approaches, is nothing blocking it, and does the door still open with the button? If so, the mechanism responds and the detection becomes the first lead. Do not open its casing. The technician checks the field, the power supply and the control box input, then tells you what needs adjusting or replacing; the written quote says so.

Wall push button of the sectional door does nothing: what should I check?

The button is only a contact: if the remote control or the other control still moves the door, the fault is the button, its cable or the control input it feeds. See whether it is pushed in, cracked or torn off the wall, without taking it apart or opening the control box. The technician tests the contact, follows the cable to the control box and checks that input; if the button is at fault, it is replaced on its own with a compatible model.

Worn motor pinion or gear: can the sectional door be repaired without changing the motor?

Often, yes. A worn pinion or gear can show as a motor that runs without the door moving, a clicking noise or a door that skips teeth mid-travel: stop the controls and call us. If the manufacturer still supplies the gear, the technician opens the gearbox and replaces it; if the housing or the shaft are worn with it, replacing the motor becomes safer, and the written quote says so.

Broken handle on an industrial sectional door: can it be replaced on its own?

Yes, if the model is still supplied. A broken handle, inside or outside, is replaced on its own without touching the door panel; a photo or the reference read on the door is enough when you call. Meanwhile, do not move the door by pulling on a panel or the seal. On a motorised door, the technician also checks that the new handle does not get in the way of the door panel’s travel in the tracks.

Industrial sectional door repairs around Pantin

All faults and prices: industrial sectional door repair in Île-de-France. Equipment: our industrial sectional doors.

All our service areas

SMS confirmation: a Shasama Fermetures technician is on the way
Rapid response

Need an intervention?

An operator on the line, a technician at your door. Available 24/7.

01 87 66 40 33Call usFree QuoteQuote −10%